{"product_id":"flygt-mp-3068-170-ht-214-1-7kw-3ph-415v-submersible-macerator-pump-5034-used","title":"Flygt MP 3068.170 HT 214 1.7KW 3PH 415V Submersible Macerator Pump #5034 USED","description":"\u003cdiv style=\"max-width:900px;margin:0 auto;padding:20px;line-height:1.6;\"\u003e\n\n  \u003ch2\u003eFlygt MP 3068.170 HT 214 – 1.7kW 3PH 415V Submersible Macerator Pump #5034 USED\u003c\/h2\u003e\n\n  \u003cp\u003eThe \u003cstrong\u003eFlygt MP 3068.170 HT 214\u003c\/strong\u003e is a submersible macerator pump for sewage and wastewater duties requiring solids reduction. Its grinder mechanism breaks down suitable solids and fibrous material before discharge, making it useful in pressure sewage systems where wastewater must be transferred through relatively small diameter pipework.\u003c\/p\u003e\n\n  \u003cp\u003e\u003cstrong\u003eFlygt is part of the Xylem Group\u003c\/strong\u003e, manufacturing pumps and equipment for wastewater collection, treatment and drainage.\u003c\/p\u003e\n\n  \u003cp\u003eThis pump is supplied \u003cstrong\u003eUSED\u003c\/strong\u003e and may show signs of previous installation, cosmetic wear, paint loss, corrosion staining or marks from service and storage. Please refer to the listing photographs for its visible condition.\u003c\/p\u003e\n\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003e1.7kW motor\u003c\/strong\u003e with three-phase electrical supply\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMacerator \/ grinder design\u003c\/strong\u003e for wastewater requiring solids reduction\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHT high-head hydraulic\u003c\/strong\u003e with curve\/impeller code 214\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eP installation\u003c\/strong\u003e for a compatible guide-rail discharge arrangement\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUsed industrial pump\u003c\/strong\u003e – stock reference #5034\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e6-month guarantee\u003c\/strong\u003e included from The Pump Dealer\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cp\u003e\u003cstrong\u003eNeed help confirming suitability?\u003c\/strong\u003e\u003cbr\u003e\n  Call us on \u003ca href=\"tel:01803220416\"\u003e\u003cstrong\u003e01803 220416\u003c\/strong\u003e\u003c\/a\u003e for technical advice.\u003c\/p\u003e\n\n  \u003chr\u003e\n\n  \u003ch3\u003eDelivery \u0026amp; Shipping\u003c\/h3\u003e\n\n  \u003cul\u003e\n    \u003cli\u003eNext working day dispatch available – order before 4pm\u003c\/li\u003e\n    \u003cli\u003eSame-day courier available – please call for a quote\u003c\/li\u003e\n    \u003cli\u003eUK and international delivery available\u003c\/li\u003e\n    \u003cli\u003eInternational shipping costs confirmed after checkout\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cp\u003e\u003cstrong\u003eManufacturer specification:\u003c\/strong\u003e\u003cbr\u003e\n  The Flygt 3068 technical specification includes several different pump variants. Refer to the \u003cstrong\u003eM-pump 3068.170\/.890\u003c\/strong\u003e section and the \u003cstrong\u003e1.7kW, three-phase, 214 curve\u003c\/strong\u003e for this listing.\u003cbr\u003e\n  \u003ca href=\"https:\/\/www.stuartgroup.co.uk\/media\/pumps\/products\/2968\/files\/Flygt_3068.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eView Flygt 3068 manufacturer technical specification, performance curves and installation drawings\u003c\/a\u003e\u003c\/p\u003e\n\n  \u003cp\u003e\u003cstrong\u003eTechnical note – voltage:\u003c\/strong\u003e\u003cbr\u003e\nVoltage is listed as 415V for search purposes. This is a three-phase 50Hz pump. Where the motor nameplate specifies \u003cstrong\u003e230V Δ \/ 400V Y\u003c\/strong\u003e, it can operate on \u003cstrong\u003e3 × 230V in Delta\u003c\/strong\u003e or \u003cstrong\u003e3 × 400V in Star\u003c\/strong\u003e. The 230V option still requires a three-phase supply and does not allow direct connection to an ordinary single-phase socket. The supply voltage, winding connection and protection settings must follow the actual motor nameplate and manufacturer instructions.\u003c\/p\u003e\n\n  \u003chr\u003e\n\n  \u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n  \u003ch4\u003eWhat does the model number mean?\u003c\/h4\u003e\n\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eM\u003c\/strong\u003e – Macerator \/ grinder hydraulic\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eP\u003c\/strong\u003e – Guide-bar wet-well installation with automatic discharge connection\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e3068\u003c\/strong\u003e – Pump series\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e.170\u003c\/strong\u003e – Non-explosion-proof model variant\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHT\u003c\/strong\u003e – High-head pressure class\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e214\u003c\/strong\u003e – Curve\/impeller reference, not a 214mm impeller diameter\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch4\u003eWhat applications is this pump suitable for?\u003c\/h4\u003e\n\n  \u003cp\u003eTypical applications include sewage collection and wastewater transfer from residential, commercial and similar premises where a pressure drainage system is required. A grinder pump can be useful when gravity drainage is impractical because of distance, elevation or site layout.\u003c\/p\u003e\n\n  \u003cp\u003eSelection should consider the wastewater composition, required flow, vertical lift and pipework resistance. Being a sewage pump does not make it suitable for every industrial effluent or slurry.\u003c\/p\u003e\n\n  \u003ch4\u003eWhat is the difference between a macerator pump and an ordinary sewage pump?\u003c\/h4\u003e\n\n  \u003cp\u003eA macerator pump reduces suitable solids using a cutting or grinding mechanism. A conventional solids-handling sewage pump generally aims to pass solids through its hydraulic passages without deliberately grinding them.\u003c\/p\u003e\n\n  \u003cp\u003eReducing solids can help with pressure sewage systems using smaller pipework, but the pipe diameter must still be selected for the required flow, friction losses and system design.\u003c\/p\u003e\n\n  \u003ch4\u003eCan it grind any material entering the sump?\u003c\/h4\u003e\n\n  \u003cp\u003eNo. A grinder should not be treated as a general waste disposal machine. Stones, metal, excessive grit and other hard or abrasive debris can damage or wear the cutting mechanism. Long fibres and unsuitable waste can still cause problems, so good wastewater management remains important.\u003c\/p\u003e\n\n  \u003ch4\u003eWhat are the main disadvantages of a macerator pump?\u003c\/h4\u003e\n\n  \u003cp\u003eThe cutting components introduce additional wear points and require inspection. Abrasive material can accelerate wear, while unsuitable objects may jam or damage the mechanism. Cutter condition and clearance can affect performance, making maintenance particularly important when assessing a used pump.\u003c\/p\u003e\n\n  \u003ch4\u003eWhat head and flow can this version produce?\u003c\/h4\u003e\n\n  \u003cp\u003eThe published three-phase 214 curve indicates approximately \u003cstrong\u003e23–24 metres shut-off head\u003c\/strong\u003e. This is the head at zero flow, not a normal operating duty.\u003c\/p\u003e\n\n  \u003cp\u003eAvailable flow decreases as system resistance increases. Maximum head and maximum flow are not delivered together. Please provide your required flow, vertical lift, pipe length and pipe diameter so suitability can be checked against the correct curve.\u003c\/p\u003e\n\n  \u003ch4\u003eWhat does the 1.7kW rating mean, and what current does it draw?\u003c\/h4\u003e\n\n  \u003cp\u003eThe 1.7kW rating is motor output, not electrical consumption. Flygt’s 400V, 50Hz reference data lists \u003cstrong\u003e3.8A rated current\u003c\/strong\u003e and \u003cstrong\u003e2695rpm\u003c\/strong\u003e.\u003c\/p\u003e\n\n  \u003cp\u003eActual electrical input depends on loading and motor efficiency. Use the fitted motor nameplate when selecting the starter, cable and overload settings.\u003c\/p\u003e\n\n  \u003ch4\u003eCan I connect this pump to an ordinary 230V or 240V socket?\u003c\/h4\u003e\n\n  \u003cp\u003eNo. This listing is for a \u003cstrong\u003ethree-phase motor\u003c\/strong\u003e, which cannot be connected directly to an ordinary single-phase socket. Any proposed alternative supply arrangement requires assessment of the actual motor and installation.\u003c\/p\u003e\n\n  \u003ch4\u003eHow is a P installation pump fitted?\u003c\/h4\u003e\n\n  \u003cp\u003eThe pump descends along two guide bars and connects automatically to a compatible discharge connection at the bottom of the wet well.\u003c\/p\u003e\n\n  \u003cp\u003eThe existing pedestal, guide arrangement and pump connection must match. The model designation alone does not confirm that guide rails, a discharge pedestal, lifting chain or other installation accessories are included with this used item.\u003c\/p\u003e\n\n  \u003ch4\u003eWill it fit my existing discharge connection?\u003c\/h4\u003e\n\n  \u003cp\u003ePlease send photographs and dimensions of your existing base connection, guide rails and pump outlet arrangement. Matching the brand or nominal pipe size alone is insufficient to establish compatibility. Any adapters or replacement fittings should be identified before purchase.\u003c\/p\u003e\n\n  \u003ch4\u003eDoes it need a separate control panel or float switch?\u003c\/h4\u003e\n\n  \u003cp\u003eAn automatic installation needs suitable motor starting, overload protection and level control. Depending on the system, level sensing may use float switches or another compatible controller.\u003c\/p\u003e\n\n  \u003cp\u003eDo not assume that a control panel, float switch or monitoring equipment is included. Any fitted motor protection or sensor connections should be identified and incorporated correctly into the installation.\u003c\/p\u003e\n\n  \u003ch4\u003eWhat are the main application limits?\u003c\/h4\u003e\n\n  \u003cp\u003eThe standard specification gives \u003cstrong\u003e40°C maximum liquid temperature\u003c\/strong\u003e, \u003cstrong\u003e20m maximum immersion depth\u003c\/strong\u003e and \u003cstrong\u003e15 starts per hour maximum\u003c\/strong\u003e.\u003c\/p\u003e\n\n  \u003cp\u003eMaximum immersion depth is not the same as delivery head. Wet-well levels and operating cycles should be set to maintain the required cooling and prevent excessive cycling or dry running.\u003c\/p\u003e\n\n  \u003ch4\u003eIs this an explosion-proof pump?\u003c\/h4\u003e\n\n  \u003cp\u003eNo. The \u003cstrong\u003e3068.170\u003c\/strong\u003e is the non-explosion-proof variant. It should not be selected for an installation requiring an Ex-certified pump.\u003c\/p\u003e\n\n  \u003ch4\u003eCan this replace my existing Flygt pump?\u003c\/h4\u003e\n\n  \u003cp\u003ePossibly, but the complete model code, electrical supply, duty point and installation connection need to be checked. Pumps within the 3068 range can have different hydraulics and performance.\u003c\/p\u003e\n\n  \u003cp\u003ePlease send a clear photograph of your existing nameplate, together with pictures of the discharge connection and installation. We can help assess suitability before purchase.\u003c\/p\u003e\n\n  \u003ch4\u003eWhat guarantee and technical support are provided?\u003c\/h4\u003e\n\n  \u003cp\u003eThis used pump includes a \u003cstrong\u003e6-month guarantee from The Pump Dealer\u003c\/strong\u003e. We also provide technical advice before purchase. Call \u003ca href=\"tel:01803220416\"\u003e\u003cstrong\u003e01803 220416\u003c\/strong\u003e\u003c\/a\u003e and quote \u003cstrong\u003estock reference #5034\u003c\/strong\u003e.\u003c\/p\u003e\n\n  \u003chr\u003e\n\n  \u003ch3\u003eAbout Our Stock\u003c\/h3\u003e\n\n  \u003cp\u003eWe specialise in supplying surplus and used industrial pumps from leading manufacturers. This listing is for the \u003cstrong\u003eused Flygt MP 3068.170 HT 214, stock reference #5034\u003c\/strong\u003e.\u003c\/p\u003e\n\n  \u003cp\u003e\u003cstrong\u003eSpecification \u0026amp; guidance notice:\u003c\/strong\u003e Technical information describes the manufacturer’s model specification. Actual performance and suitability depend on the condition of the supplied equipment, system design, pipework losses, pumped media and installation. Check the nameplate, listing photographs and manufacturer documentation, and contact us before purchasing if you need confirmation of any connection, accessory or application requirement.\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Flygt","offers":[{"title":"Default Title","offer_id":64947574964601,"sku":null,"price":795.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1218\/7894\/files\/ddf75ef3-9010-43e9-a024-9d47728379a2.jpg?v=1792498195","url":"https:\/\/thepumpdealer.co.uk\/products\/flygt-mp-3068-170-ht-214-1-7kw-3ph-415v-submersible-macerator-pump-5034-used","provider":"The Pump Dealer","version":"1.0","type":"link"}