{"product_id":"grundfos-cm-1-6-a-r-g-e-aqqe-c-a-a-n-horizontal-multistage-pump-240v-97516642-5002","title":"Grundfos CM 1-6 A R G E AQQE C A A N Horizontal Multistage Pump 240v 97516642 #5002","description":"\u003cdiv style=\"max-width: 900px; margin: 0 auto; padding: 20px; line-height: 1.6;\"\u003e\n\n\u003ch2\u003eGrundfos CM 1-6 A-R-G-E-AQQE C-A-A-N Horizontal Multistage Pump 240V 97516642 #5002\u003c\/h2\u003e\n\n\u003cp\u003e\nThis listing is for a \u003cstrong\u003eGrundfos CM 1-6 A-R-G-E-AQQE C-A-A-N horizontal multistage centrifugal pump\u003c\/strong\u003e, product number \u003cstrong\u003e97516642\u003c\/strong\u003e. It is a compact, mains-operated Grundfos CM pump with \u003cstrong\u003e316 stainless steel wetted parts\u003c\/strong\u003e, \u003cstrong\u003ethreaded Rp pipe connections\u003c\/strong\u003e and a \u003cstrong\u003esingle-phase 220–240V motor\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe Grundfos CM range is designed for clean-water and compatible liquid duties where a compact horizontal multistage pump is required. Typical uses include pressure boosting, water transfer, washing and cleaning systems, temperature-control circuits, water treatment and compatible clean industrial process duties.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e supplied in \u003cstrong\u003eas new surplus condition\u003c\/strong\u003e – the pump has not been installed or used but may show minor cosmetic markings from storage and handling. \u003cstrong\u003eGuarantee:\u003c\/strong\u003e supplied with a \u003cstrong\u003e2-year guarantee\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Grundfos\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CM 1-6 A-R-G-E-AQQE C-A-A-N\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct number:\u003c\/strong\u003e 97516642\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStock code:\u003c\/strong\u003e #5002\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePump type:\u003c\/strong\u003e horizontal multistage end-suction centrifugal pump\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCM version:\u003c\/strong\u003e CM-G stainless steel wetted construction\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpeed type:\u003c\/strong\u003e fixed speed \/ mains-operated motor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSelf-priming:\u003c\/strong\u003e no – normal-suction pump, must be correctly flooded \/ primed before operation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of impellers \/ stages:\u003c\/strong\u003e 6\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication type:\u003c\/strong\u003e clean-water transfer, pressure boosting, washing, water treatment, temperature control and compatible industrial liquid transfer\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated flow:\u003c\/strong\u003e 1.7 m³\/h \/ 0.47 L\/s\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated head:\u003c\/strong\u003e 36.3 m\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum operating pressure:\u003c\/strong\u003e 16 bar\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax pressure at stated temperature:\u003c\/strong\u003e 10 bar \/ 120°C and 16 bar \/ 90°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLiquid temperature range:\u003c\/strong\u003e -20°C to +120°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum ambient temperature:\u003c\/strong\u003e 55°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Whitworth pipe thread Rp \/ ISO 7\/1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuction connection:\u003c\/strong\u003e Rp 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDischarge connection:\u003c\/strong\u003e Rp 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePipework arrangement:\u003c\/strong\u003e axial suction and radial discharge\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated motor power:\u003c\/strong\u003e 0.5 kW\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e single-phase, 50 Hz, 1 × 220–240V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal voltage listing:\u003c\/strong\u003e 230V \/ 240V single-phase\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 3.1–2.8 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStarting current:\u003c\/strong\u003e 530%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated speed:\u003c\/strong\u003e 2730–2740 rpm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor frame:\u003c\/strong\u003e 71B\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor type:\u003c\/strong\u003e single-phase foot-mounted fan-cooled asynchronous motor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure class:\u003c\/strong\u003e IP55\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation class:\u003c\/strong\u003e F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor protection:\u003c\/strong\u003e built-in thermal protection \/ TP211\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShaft seal:\u003c\/strong\u003e AQQE mechanical shaft seal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAQQE seal materials:\u003c\/strong\u003e O-ring seal with fixed seal driver, silicon carbide \/ silicon carbide seal faces and EPDM elastomers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRubber parts:\u003c\/strong\u003e EPDM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePump housing material:\u003c\/strong\u003e stainless steel EN 1.4401 \/ AISI 316\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eImpeller material:\u003c\/strong\u003e stainless steel EN 1.4401 \/ AISI 316\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Efficiency Index:\u003c\/strong\u003e MEI ≥ 0.68\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApprovals shown:\u003c\/strong\u003e CE, WRAS, ACS, TR, EAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurve tolerance:\u003c\/strong\u003e ISO 9906:2012 3B\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet weight:\u003c\/strong\u003e approx. 13.7 kg\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGross weight:\u003c\/strong\u003e approx. 16.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eNeed help confirming suitability?\u003c\/strong\u003e\u003cbr\u003e\nCall us on \u003cstrong\u003e01803 220416\u003c\/strong\u003e for technical advice.\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch3\u003eManufacturer product page\u003c\/h3\u003e\n\n\u003cp\u003e\nThe official Grundfos product page for this pump can be viewed here:\u003cbr\u003e\n\u003ca href=\"https:\/\/product-selection.grundfos.com\/uk\/products\/cm-cme\/cm\/cm-1-6-97516642\" rel=\"nofollow noopener\" target=\"_blank\"\u003e\nView Grundfos CM 1-6 A-R-G-E-AQQE C-A-A-N – 97516642\n\u003c\/a\u003e\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch3\u003eTechnical documentation\u003c\/h3\u003e\n\n\u003cp\u003e\nGrundfos specification sheet and dimensional drawing for product number 97516642:\u003cbr\u003e\n\u003ca href=\"https:\/\/www.lenntech.com\/uploads\/grundfos\/97516642\/Grundfos_CM1-6-A-R-G-E-AQQE.pdf\" rel=\"nofollow noopener\" target=\"_blank\"\u003e\nView Grundfos CM 1-6 A-R-G-E-AQQE specification sheet and dimensional drawing\n\u003c\/a\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\nGrundfos CME \/ CM data booklet:\u003cbr\u003e\n\u003ca href=\"https:\/\/api.grundfos.com\/literature\/Grundfosliterature-5060.pdf\" rel=\"nofollow noopener\" target=\"_blank\"\u003e\nView Grundfos CME and CM data booklet\n\u003c\/a\u003e\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eClean-water transfer\u003c\/li\u003e\n  \u003cli\u003ePressure boosting in domestic, commercial or industrial water systems\u003c\/li\u003e\n  \u003cli\u003eWater treatment and smaller reverse-osmosis support duties\u003c\/li\u003e\n  \u003cli\u003eWashing and cleaning systems\u003c\/li\u003e\n  \u003cli\u003eVehicle-wash and wash-down systems\u003c\/li\u003e\n  \u003cli\u003eTemperature-control circuits\u003c\/li\u003e\n  \u003cli\u003eCooling and air-conditioning support duties\u003c\/li\u003e\n  \u003cli\u003eLevel control and tank filling applications\u003c\/li\u003e\n  \u003cli\u003eCompatible clean industrial liquid transfer\u003c\/li\u003e\n  \u003cli\u003eApplications requiring 316 stainless steel wetted parts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003ch4\u003eWhat is this pump used for?\u003c\/h4\u003e\n\n\u003cp\u003e\nThis Grundfos CM 1-6 is used for clean-water transfer, pressure boosting, washing, water treatment, temperature control and compatible industrial circulation duties. It is a compact horizontal multistage pump designed to produce a higher head from a relatively small flow rate.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat does CM mean?\u003c\/h4\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eCM\u003c\/strong\u003e stands for Grundfos’ compact horizontal multistage pump range. CM pumps are close-coupled pumps with a standard mains-operated motor and a mechanical shaft seal. They are designed for clean-liquid duties where compact size, quiet operation and reliable pressure performance are required.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat does CM 1-6 mean?\u003c\/h4\u003e\n\n\u003cp\u003e\nIn the Grundfos model code, \u003cstrong\u003e1\u003c\/strong\u003e refers to the rated flow family at 50Hz, and \u003cstrong\u003e6\u003c\/strong\u003e indicates the number of impellers \/ hydraulic stages. This version is a six-stage CM 1 pump, giving a rated duty point of approximately \u003cstrong\u003e1.7 m³\/h\u003c\/strong\u003e at \u003cstrong\u003e36.3 m head\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat does A-R-G-E-AQQE mean?\u003c\/h4\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e – basic pump version\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eR\u003c\/strong\u003e – Whitworth threaded Rp pipe connection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eG\u003c\/strong\u003e – stainless steel wetted construction, EN 1.4401 \/ AISI 316\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eE\u003c\/strong\u003e – EPDM rubber parts in the pump, excluding neck ring and shaft seal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAQQE\u003c\/strong\u003e – mechanical shaft seal code\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eWhat does C-A-A-N mean?\u003c\/h4\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eC\u003c\/strong\u003e – single-phase 220–240V, 50Hz supply version\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e – standard motor, IP55\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e – prepared for cable glands\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e – no sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eWhat is the AQQE shaft seal?\u003c\/h4\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eAQQE\u003c\/strong\u003e is the Grundfos shaft seal code. It indicates an \u003cstrong\u003eO-ring mechanical shaft seal with fixed seal driver\u003c\/strong\u003e, \u003cstrong\u003esilicon carbide \/ silicon carbide seal faces\u003c\/strong\u003e and \u003cstrong\u003eEPDM secondary elastomers\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe silicon carbide \/ silicon carbide face pairing gives good wear resistance in compatible clean-liquid duties. EPDM is well suited to many water-based applications and hot-water duties, but it is not suitable for mineral oils or fuel-related liquids.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat is the difference between CM-I and CM-G?\u003c\/h4\u003e\n\n\u003cp\u003e\nGrundfos CM-I pumps use stainless steel EN 1.4301 \/ AISI 304 wetted parts. This pump is the \u003cstrong\u003eCM-G\u003c\/strong\u003e version, which uses stainless steel \u003cstrong\u003eEN 1.4401 \/ AISI 316\u003c\/strong\u003e wetted parts. AISI 316 offers improved corrosion resistance compared with AISI 304 in selected compatible duties.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat voltage is this pump?\u003c\/h4\u003e\n\n\u003cp\u003e\nThis pump is a \u003cstrong\u003esingle-phase 220–240V, 50Hz\u003c\/strong\u003e pump. For UK supplies, it is normally listed as a \u003cstrong\u003e230V \/ 240V single-phase pump\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003ch4\u003eDoes the motor need overload protection?\u003c\/h4\u003e\n\n\u003cp\u003e\nThe motor has built-in thermal protection \/ TP211. The product documentation states that the motor has built-in thermal protection and requires no further motor protection. Because the protection includes automatic reset, the installation must be arranged so that automatic restart cannot create a hazard during servicing or fault conditions.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat flow and pressure does this pump produce?\u003c\/h4\u003e\n\n\u003cp\u003e\nThe listed rated duty point is \u003cstrong\u003e1.7 m³\/h\u003c\/strong\u003e at \u003cstrong\u003e36.3 m head\u003c\/strong\u003e. Actual performance depends on the installed pipework, system resistance, inlet pressure and operating point on the pump curve.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat pipe connections does this pump have?\u003c\/h4\u003e\n\n\u003cp\u003e\nThis pump has threaded Rp pipe connections to ISO 7\/1. Both the suction and discharge connections are \u003cstrong\u003eRp 1\u003c\/strong\u003e. It is not a flanged pump.\n\u003c\/p\u003e\n\n\u003ch4\u003eIs this pump self-priming?\u003c\/h4\u003e\n\n\u003cp\u003e\nNo. This is a normal-suction CM pump, not a CM self-priming version. The pump must be correctly flooded or primed before operation and must not be run dry.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat liquids is this pump suitable for?\u003c\/h4\u003e\n\n\u003cp\u003e\nThis pump is suitable for \u003cstrong\u003eclean, thin, non-aggressive and non-explosive liquids\u003c\/strong\u003e compatible with stainless steel EN 1.4401 \/ AISI 316, EPDM elastomers and the AQQE mechanical shaft seal.\n\u003c\/p\u003e\n\n\u003cp\u003e\nTypical suitable duties include clean water, treated water and compatible water-based process liquids. Liquids with a viscosity or density different from water can affect pump performance and motor load, so the duty should be checked before use.\n\u003c\/p\u003e\n\n\u003ch4\u003eCan this pump handle dirty water or solids?\u003c\/h4\u003e\n\n\u003cp\u003e\nNo. This is a clean-liquid multistage centrifugal pump. It is not designed for dirty water, wastewater, sewage, sludge, fibres or liquids containing abrasive solids. Particles can damage the hydraulic stages and mechanical shaft seal.\n\u003c\/p\u003e\n\n\u003ch4\u003eIs this suitable for potable water?\u003c\/h4\u003e\n\n\u003cp\u003e\nThe product documentation shows WRAS and ACS approvals for this pump. Final suitability for potable water still depends on the full installation, water quality, local regulations and any site-specific requirements.\n\u003c\/p\u003e\n\n\u003ch4\u003eIs this suitable for hot water?\u003c\/h4\u003e\n\n\u003cp\u003e\nGrundfos lists a liquid temperature range of \u003cstrong\u003e-20°C to +120°C\u003c\/strong\u003e for this product. The specification also lists maximum pressure at stated temperature as \u003cstrong\u003e10 bar at 120°C\u003c\/strong\u003e and \u003cstrong\u003e16 bar at 90°C\u003c\/strong\u003e. Hot-water suitability depends on the liquid, pressure, water quality, seal condition and installation conditions.\n\u003c\/p\u003e\n\n\u003ch4\u003eIs this suitable for glycol?\u003c\/h4\u003e\n\n\u003cp\u003e\nThe AQQE seal uses EPDM elastomers and silicon carbide \/ silicon carbide seal faces, which may be suitable for selected water-glycol duties. Glycol type, concentration, viscosity, temperature and inhibitor package can affect pump performance and seal life, so the exact duty should be checked before use.\n\u003c\/p\u003e\n\n\u003ch4\u003eIs this suitable for oils or fuels?\u003c\/h4\u003e\n\n\u003cp\u003e\nNot as a standard configuration. This pump is fitted with an \u003cstrong\u003eAQQE\u003c\/strong\u003e mechanical shaft seal using \u003cstrong\u003esilicon carbide \/ silicon carbide seal faces\u003c\/strong\u003e and \u003cstrong\u003eEPDM elastomers\u003c\/strong\u003e. EPDM is generally selected for water-based duties rather than mineral oils or fuel-related liquids.\n\u003c\/p\u003e\n\n\u003cp\u003e\nFor mineral oil, diesel, petrol, fuel oil or similar hydrocarbon duties, the exact liquid, temperature, viscosity, pressure and seal compatibility must be checked. A different seal and elastomer selection would normally be required for oil or fuel applications.\n\u003c\/p\u003e\n\n\u003ch4\u003eCan this be used as a pressure boosting pump?\u003c\/h4\u003e\n\n\u003cp\u003e\nYes, subject to correct sizing and system design. CM pumps are commonly used for pressure boosting and water transfer duties. The pump should be selected against the required flow, head, inlet pressure, available NPSH and control arrangement.\n\u003c\/p\u003e\n\n\u003ch4\u003eCan this pump be used with a variable-speed drive?\u003c\/h4\u003e\n\n\u003cp\u003e\nThis is a fixed-speed CM pump with a standard mains-operated motor, not a CME pump with an integrated frequency converter. If external variable-speed control is required, the motor and installation should be checked for inverter suitability before use.\n\u003c\/p\u003e\n\n\u003ch4\u003eHow should this pump be installed?\u003c\/h4\u003e\n\n\u003cp\u003e\nThe pump should be installed on a level surface and fixed so that it cannot move during starting or operation. It should be installed so that air pockets are avoided in the pump housing and pipework, with suitable access for inspection, maintenance and service.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat should I check before ordering?\u003c\/h4\u003e\n\n\u003cul\u003e\n  \u003cli\u003eProduct number: 97516642\u003c\/li\u003e\n  \u003cli\u003eModel: CM 1-6 A-R-G-E-AQQE C-A-A-N\u003c\/li\u003e\n  \u003cli\u003eElectrical supply: single-phase 220–240V \/ 230V \/ 240V class\u003c\/li\u003e\n  \u003cli\u003eConnection sizes: Rp 1 suction and Rp 1 discharge\u003c\/li\u003e\n  \u003cli\u003eRequired flow and head duty point\u003c\/li\u003e\n  \u003cli\u003ePumped liquid compatibility with AISI 316 stainless steel, EPDM and AQQE seal materials\u003c\/li\u003e\n  \u003cli\u003eMaximum operating pressure and liquid temperature\u003c\/li\u003e\n  \u003cli\u003eWhether a normal-suction pump is suitable for the installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch3\u003eAbout Our Stock\u003c\/h3\u003e\n\n\u003cp\u003e\nStock code: \u003cstrong\u003e#5002\u003c\/strong\u003e\u003cbr\u003e\nWe specialise in supplying \u003cstrong\u003enew and unused surplus commercial pump equipment\u003c\/strong\u003e. This pump is supplied in \u003cstrong\u003eas new surplus condition\u003c\/strong\u003e and may show minor cosmetic marks from storage and handling.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThis item is supplied with a \u003cstrong\u003e2-year guarantee\u003c\/strong\u003e. Please check the product number, voltage, connection sizes, duty point and liquid compatibility carefully before purchase.\n\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":63785813967225,"sku":null,"price":695.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1218\/7894\/files\/3ff67ac8-ef7c-4432-a8b5-e736dab290f9.jpg?v=1781700993","url":"https:\/\/thepumpdealer.co.uk\/products\/grundfos-cm-1-6-a-r-g-e-aqqe-c-a-a-n-horizontal-multistage-pump-240v-97516642-5002","provider":"The Pump Dealer","version":"1.0","type":"link"}