{"product_id":"grundfos-tp-50-190-2-a-f-a-bqqe-1-5kw-dn50-inline-circulator-pump-415v-96086996-used-5015","title":"Grundfos TP 50-190\/2 A-F-A-BQQE 1.5kW DN50 Inline Circulator Pump 415V 96086996 USED #5015","description":"\u003cdiv style=\"max-width: 900px; margin: 0 auto; padding: 20px; line-height: 1.6;\"\u003e\n\u003ch2\u003eGrundfos TP 50-190\/2 A-F-A-BQQE DN50 Flanged In-Line Pump 415V 1.5kW 96086996 #5015 USED\u003c\/h2\u003e\n\u003cp\u003eThis listing is for a \u003cstrong\u003eGrundfos TP 50-190\/2 A-F-A-BQQE single-stage in-line centrifugal circulator pump\u003c\/strong\u003e, product number \u003cstrong\u003e96086996\u003c\/strong\u003e. It is a fixed-speed, dry-rotor commercial heating and cooling pump with \u003cstrong\u003eDN50 PN16 DIN flanged connections\u003c\/strong\u003e, a \u003cstrong\u003e340 mm port-to-port length\u003c\/strong\u003e and a \u003cstrong\u003e1.5 kW three-phase 400V \/ 415V motor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe Grundfos TP range is designed for commercial heating, cooling, HVAC and compatible industrial circulation duties. Its in-line construction allows installation directly into matching pipework, while the top-pull-out design enables removal of the motor, pump head and impeller for maintenance without removing the pump housing from the pipework.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e supplied as a \u003cstrong\u003eUSED pump\u003c\/strong\u003e. The unit has previously been installed and may show cosmetic wear consistent with service use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant condition note:\u003c\/strong\u003e There is a \u003cstrong\u003ecrack to the motor cooling-fan cowl (fan cover)\u003c\/strong\u003e. Please refer to the product photographs. The fan guard should be inspected and repaired or replaced where necessary before operation to ensure the cooling fan remains safely guarded and airflow is unobstructed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGuarantee:\u003c\/strong\u003e supplied with a \u003cstrong\u003e6-month guarantee\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Grundfos\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e TP 50-190\/2 A-F-A-BQQE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrundfos product number:\u003c\/strong\u003e 96086996\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStock code:\u003c\/strong\u003e #5015\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 5700395309522\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump type:\u003c\/strong\u003e Single-stage dry-rotor in-line centrifugal pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed type:\u003c\/strong\u003e Fixed speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e DN50 inlet \/ DN50 outlet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e DIN flanged, EN 1092-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlange pressure rating:\u003c\/strong\u003e PN16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort-to-port length:\u003c\/strong\u003e 340 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum operating pressure:\u003c\/strong\u003e 16 bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum head:\u003c\/strong\u003e 190 dm \/ 19 metres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated flow:\u003c\/strong\u003e 22.2 m³\/h \/ 6.17 L\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated head:\u003c\/strong\u003e 15.5 metres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum flow reference:\u003c\/strong\u003e Approximately 28 m³\/h \/ 7.78 L\/s at low differential head\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActual impeller diameter:\u003c\/strong\u003e 120 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated motor output P2:\u003c\/strong\u003e 1.5 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical supply:\u003c\/strong\u003e 3-phase, 50Hz, 3 × 220–240V Delta \/ 380–415V Star\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal UK supply:\u003c\/strong\u003e 400V \/ 415V three-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated speed:\u003c\/strong\u003e Approximately 2890–2910 rpm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor:\u003c\/strong\u003e 2-pole, fan-cooled asynchronous motor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor efficiency class:\u003c\/strong\u003e IE3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor enclosure class:\u003c\/strong\u003e IP55 manufacturer's standard specification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor insulation class:\u003c\/strong\u003e F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor protection:\u003c\/strong\u003e Requires external overload protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShaft seal:\u003c\/strong\u003e BQQE mechanical shaft seal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeal construction:\u003c\/strong\u003e Rubber bellows mechanical seal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeal faces:\u003c\/strong\u003e Silicon carbide \/ silicon carbide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecondary seal material:\u003c\/strong\u003e EPDM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid temperature range:\u003c\/strong\u003e -25°C to +120°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump housing material:\u003c\/strong\u003e Cast iron EN-GJL-250 \/ EN-JL1040\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpeller material:\u003c\/strong\u003e Cast iron EN-GJL-200 \/ EN-JL1030\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Efficiency Index:\u003c\/strong\u003e MEI ≥ 0.70\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e USED – crack to motor fan cowl\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGuarantee:\u003c\/strong\u003e 6 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical note:\u003c\/strong\u003e Published motor details vary slightly between production versions. The fitted motor nameplate should be used to confirm the exact rated current and overload setting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed help confirming suitability?\u003c\/strong\u003e\u003cbr\u003eCall us on \u003cstrong\u003e01803 220416\u003c\/strong\u003e for technical advice.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eManufacturer Product Page\u003c\/h3\u003e\n\u003cp\u003eThe official Grundfos product page for this pump can be viewed here:\u003cbr\u003e\u003ca href=\"https:\/\/product-selection.grundfos.com\/uk\/products\/tp-tpe\/tp\/tp-50-1902-96086996\" rel=\"nofollow noopener\" target=\"_blank\"\u003e View Grundfos TP 50-190\/2 – 96086996 \u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Documentation\u003c\/h3\u003e\n\u003cp\u003eGrundfos product-specific technical data, including performance curves, motor data, installation dimensions and electrical connection diagrams:\u003cbr\u003e\u003ca href=\"https:\/\/www.anglianpumping.com\/app\/uploads\/2023\/03\/96086996_TP_50-1902_A-F-A-BQQE.pdf?utm_source=chatgpt.com\" rel=\"nofollow noopener\" target=\"_blank\"\u003e View Grundfos TP 50-190\/2 Specification Sheet and Dimensional Drawing \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eGrundfos TP \/ TPD \/ TPE \/ TPED technical data booklet:\u003cbr\u003e\u003ca href=\"https:\/\/api.grundfos.com\/literature\/Grundfosliterature-1580.pdf\" rel=\"nofollow noopener\" target=\"_blank\"\u003e View Grundfos TP and TPD Technical Data Booklet \u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial heating circulation systems\u003c\/li\u003e\n\u003cli\u003eBoiler primary and secondary circuits\u003c\/li\u003e\n\u003cli\u003eHVAC circulation systems\u003c\/li\u003e\n\u003cli\u003eDistrict heating and cooling circuits\u003c\/li\u003e\n\u003cli\u003eAir-conditioning and chilled-water circulation\u003c\/li\u003e\n\u003cli\u003eIndustrial cooling and temperature-control systems\u003c\/li\u003e\n\u003cli\u003eCompatible clean-water circulation duties\u003c\/li\u003e\n\u003cli\u003eReplacement of matching DN50 flanged Grundfos TP installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is this pump used for?\u003c\/h4\u003e\n\u003cp\u003eThe Grundfos TP 50-190\/2 is a \u003cstrong\u003ecommercial dry-rotor in-line centrifugal pump\u003c\/strong\u003e designed for circulating water in heating, cooling, HVAC and compatible industrial systems.\u003c\/p\u003e\n\u003cp\u003eIt is particularly suitable for applications requiring a relatively high flow rate against a moderate pressure loss, with a rated duty point of \u003cstrong\u003e22.2 m³\/h at 15.5 metres head\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eWhat does TP 50-190\/2 mean?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTP:\u003c\/strong\u003e Grundfos single-stage dry-rotor in-line centrifugal pump range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50:\u003c\/strong\u003e Nominal DN50 inlet and outlet connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e190:\u003c\/strong\u003e Maximum head class of 190 decimetres, approximately 19 metres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\/2:\u003c\/strong\u003e Two-pole motor, operating at approximately 2900 rpm on a 50Hz supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat does A-F-A-BQQE mean?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e Basic pump version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF:\u003c\/strong\u003e DIN flanged pipe connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e Basic material configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBQQE:\u003c\/strong\u003e Mechanical shaft seal code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat is the BQQE shaft seal?\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong\u003eBQQE\u003c\/strong\u003e seal is a rubber bellows mechanical shaft seal with \u003cstrong\u003esilicon carbide \/ silicon carbide seal faces\u003c\/strong\u003e and \u003cstrong\u003eEPDM secondary elastomers\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe silicon carbide seal faces provide excellent hardness and good wear resistance, while the EPDM elastomers are particularly suitable for many clean-water and hot-water duties.\u003c\/p\u003e\n\u003cp\u003eThe rubber bellows construction allows axial movement of the seal without relying on an O-ring sliding along the pump shaft. This helps prevent deposits on the shaft from restricting seal movement.\u003c\/p\u003e\n\u003ch4\u003eWhat temperature and pressure can this pump operate at?\u003c\/h4\u003e\n\u003cp\u003eGrundfos lists a liquid temperature range of \u003cstrong\u003e-25°C to +120°C\u003c\/strong\u003e for this BQQE configuration, with a maximum operating pressure of \u003cstrong\u003e16 bar\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe maximum operating pressure applies to the complete pump system and should not be confused with the differential pressure generated by the pump.\u003c\/p\u003e\n\u003cp\u003eOperation at high temperatures requires sufficient inlet pressure to prevent cavitation and ensure adequate lubrication of the shaft seal.\u003c\/p\u003e\n\u003ch4\u003eWhat liquids can this pump circulate?\u003c\/h4\u003e\n\u003cp\u003eThis pump is suitable for \u003cstrong\u003ethin, clean, non-aggressive and non-flammable liquids\u003c\/strong\u003e compatible with its cast-iron construction and BQQE mechanical shaft seal.\u003c\/p\u003e\n\u003cp\u003eTypical suitable duties include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClean heating system water\u003c\/li\u003e\n\u003cli\u003eCommercial cooling water\u003c\/li\u003e\n\u003cli\u003eChilled-water circulation\u003c\/li\u003e\n\u003cli\u003eAir-conditioning circulation water\u003c\/li\u003e\n\u003cli\u003eDistrict heating and cooling water\u003c\/li\u003e\n\u003cli\u003eCompatible treated and softened water\u003c\/li\u003e\n\u003cli\u003eSelected water-glycol mixtures\u003c\/li\u003e\n\u003cli\u003eCompatible clean industrial circulation liquids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe pump is not intended for sewage, wastewater, sludge, abrasive solids, fibres or liquids that chemically attack its components.\u003c\/p\u003e\n\u003ch4\u003eCan this pump be used with glycol?\u003c\/h4\u003e\n\u003cp\u003eYes, subject to the mixture and operating conditions. Grundfos recommends \u003cstrong\u003eBQQE or DQQE shaft seals\u003c\/strong\u003e for certain TP pump duties involving glycol or antifreeze mixtures. This pump is fitted with \u003cstrong\u003eBQQE\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eGlycol type, concentration, viscosity and inhibitor package affect pump performance and seal life. Higher viscosity can increase motor load and may require the pump duty to be reassessed.\u003c\/p\u003e\n\u003cp\u003eThe exact liquid mixture should therefore be checked against Grundfos liquid compatibility guidance before installation.\u003c\/p\u003e\n\u003ch4\u003eIs this suitable for mineral oils or fuels?\u003c\/h4\u003e\n\u003cp\u003eNot with the standard BQQE seal arrangement.\u003c\/p\u003e\n\u003cp\u003eThe fitted seal uses \u003cstrong\u003eEPDM elastomers\u003c\/strong\u003e, which are generally suitable for many water-based duties but are not compatible with mineral oils and petroleum-based fuels.\u003c\/p\u003e\n\u003cp\u003eOil or fuel applications normally require a different seal and material selection. This pump should not be used for flammable or explosive liquids without specific approval for the complete application.\u003c\/p\u003e\n\u003ch4\u003eIs this suitable for potable water?\u003c\/h4\u003e\n\u003cp\u003eThis is a \u003cstrong\u003ecast-iron commercial circulator\u003c\/strong\u003e primarily intended for heating, cooling and industrial circulation duties.\u003c\/p\u003e\n\u003cp\u003eAlthough the wider Grundfos TP range includes pumps used in water supply applications, this standard cast-iron version should not automatically be regarded as suitable for potable domestic hot-water systems.\u003c\/p\u003e\n\u003cp\u003eFor drinking-water or domestic hot-water circulation, the pump materials, water quality and relevant approvals must be checked.\u003c\/p\u003e\n\u003ch4\u003eWhat is the advantage of the top-pull-out design?\u003c\/h4\u003e\n\u003cp\u003eThe Grundfos TP uses a \u003cstrong\u003etop-pull-out construction\u003c\/strong\u003e, allowing the motor, pump head and impeller assembly to be removed for inspection or maintenance while the main pump housing remains installed in the pipework.\u003c\/p\u003e\n\u003cp\u003eThis can simplify servicing and reduce the need to disturb existing flanges and pipework.\u003c\/p\u003e\n\u003ch4\u003eIs this a variable-speed pump?\u003c\/h4\u003e\n\u003cp\u003eNo. This is a \u003cstrong\u003efixed-speed TP pump\u003c\/strong\u003e with a standard three-phase asynchronous motor.\u003c\/p\u003e\n\u003cp\u003eGrundfos documentation identifies the possibility of using a suitable external variable-frequency drive, such as a Grundfos CUE, where speed control is required.\u003c\/p\u003e\n\u003cp\u003eAny inverter installation must be correctly matched to the fitted motor and commissioned with suitable electrical protection.\u003c\/p\u003e\n\u003ch4\u003eWhat electrical supply does this pump require?\u003c\/h4\u003e\n\u003cp\u003eThe pump has a three-phase, 50Hz motor rated for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e220–240V Delta\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e380–415V Star\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a normal UK 400V \/ 415V three-phase supply, the motor is connected in the appropriate star configuration according to its nameplate and wiring diagram.\u003c\/p\u003e\n\u003cp\u003eThe motor requires suitable external overload protection because it does not incorporate built-in motor protection.\u003c\/p\u003e\n\u003ch4\u003eWhat is the minimum inlet pressure or NPSH requirement?\u003c\/h4\u003e\n\u003cp\u003eThe required minimum inlet pressure depends on liquid temperature, operating flow and the available suction conditions.\u003c\/p\u003e\n\u003cp\u003eGrundfos provides an \u003cstrong\u003eNPSH curve\u003c\/strong\u003e in the product-specific technical documentation. This should be used when assessing installations with elevated water temperatures, restricted suction pipework or limited available inlet pressure.\u003c\/p\u003e\n\u003cp\u003eInsufficient inlet pressure can cause cavitation, noise, reduced performance and premature damage to the impeller and shaft seal.\u003c\/p\u003e\n\u003cp\u003eThe pump must always be correctly filled and vented before operation.\u003c\/p\u003e\n\u003ch4\u003eWill this replace my existing DN50 TP pump?\u003c\/h4\u003e\n\u003cp\u003eThis pump has \u003cstrong\u003eDN50 PN16 DIN flanged connections\u003c\/strong\u003e, a \u003cstrong\u003e340 mm port-to-port length\u003c\/strong\u003e and a \u003cstrong\u003e1.5 kW three-phase motor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt may replace an existing matching Grundfos TP pump or a comparable in-line circulator from manufacturers such as \u003cstrong\u003eWilo, Lowara or KSB\u003c\/strong\u003e, provided the hydraulic duty, flange standard, installation dimensions and electrical requirements are suitable.\u003c\/p\u003e\n\u003cp\u003eThe pump should be selected against the required flow and head rather than connection size alone.\u003c\/p\u003e\n\u003ch4\u003eWhat is the condition of the motor fan cowl?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThere is a crack in the motor cooling-fan cowl.\u003c\/strong\u003e This is an existing defect and is disclosed as part of the used condition of the pump.\u003c\/p\u003e\n\u003cp\u003eThe fan cowl is the protective cover around the motor's external cooling fan. It helps prevent contact with the rotating fan while allowing cooling air to circulate around the motor.\u003c\/p\u003e\n\u003cp\u003eA cracked fan cowl should be inspected before operation. If the cover is insecure, damaged sufficiently to expose the fan or obstructs cooling airflow, it should be repaired or replaced before commissioning.\u003c\/p\u003e\n\u003cp\u003ePlease refer to the product photographs for the condition of the supplied unit.\u003c\/p\u003e\n\u003ch4\u003eWhat should I check before ordering?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eExisting pump model and product number\u003c\/li\u003e\n\u003cli\u003eRequired flow and head duty point\u003c\/li\u003e\n\u003cli\u003eDN50 PN16 flange compatibility\u003c\/li\u003e\n\u003cli\u003e340 mm port-to-port installation length\u003c\/li\u003e\n\u003cli\u003eThree-phase 400V \/ 415V electrical supply\u003c\/li\u003e\n\u003cli\u003eMotor overload protection and controls\u003c\/li\u003e\n\u003cli\u003ePumped-liquid compatibility and temperature\u003c\/li\u003e\n\u003cli\u003eAvailable inlet pressure \/ NPSH requirements\u003c\/li\u003e\n\u003cli\u003eCondition of the motor fan cowl\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eAbout Our Stock\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eStock code: #5015\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe specialise in supplying \u003cstrong\u003eused, surplus and obsolete commercial pumps and pumping equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis pump is supplied in \u003cstrong\u003eUSED condition\u003c\/strong\u003e and has a \u003cstrong\u003ecrack to the motor cooling-fan cowl\u003c\/strong\u003e, as described above.\u003c\/p\u003e\n\u003cp\u003eSupplied with a \u003cstrong\u003e6-month guarantee\u003c\/strong\u003e. Please check the product number, electrical supply, flange dimensions, hydraulic performance and disclosed condition before purchasing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e```\u003c\/p\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":64937214312825,"sku":null,"price":695.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1218\/7894\/files\/0f3aa4d3-73b0-4874-b6d2-9a5a2ced5925.jpg?v=1792417730","url":"https:\/\/thepumpdealer.co.uk\/products\/grundfos-tp-50-190-2-a-f-a-bqqe-1-5kw-dn50-inline-circulator-pump-415v-96086996-used-5015","provider":"The Pump Dealer","version":"1.0","type":"link"}