{"product_id":"grundfos-tpd-100-160-2-a-f-a-bqqe-kw1-flanged-pump-heating-circulator-415v-dn100-96109245-4950","title":"Grundfos TPD 100-160\/2 A-F-A-BQQE-KW1 Flanged Pump Heating Circulator 415v Dn100 96109245 #4950 USED","description":"\u003cdiv style=\"max-width: 900px; margin: 0 auto; padding: 20px; line-height: 1.6;\"\u003e\n\n\u003ch2\u003eGrundfos TPD 100-160\/2 A-F-A-BQQE-KW1 Flanged Pump Heating Circulator 415V DN100 96109245 #4950 USED\u003c\/h2\u003e\n\n\u003cp\u003e\nThis listing is for a \u003cstrong\u003eused Grundfos TPD 100-160\/2 A-F-A-BQQE-KW1 twin-head in-line circulator pump\u003c\/strong\u003e. It is a fixed-speed, dry-rotor, commercial heating and cooling circulation pump with \u003cstrong\u003eDN100 DIN flanged connections\u003c\/strong\u003e, \u003cstrong\u003ePN16 pressure rating\u003c\/strong\u003e and \u003cstrong\u003e3-phase 415V class electrical supply\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe TPD range is designed as a \u003cstrong\u003etwin-head in-line pump\u003c\/strong\u003e, giving two pump heads in one common pump body. This arrangement is commonly used in commercial heating, cooling and HVAC circulation systems where duty\/standby operation or alternating pump operation is required.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e supplied as a \u003cstrong\u003eused pump\u003c\/strong\u003e. The unit has been previously installed\/used and may show cosmetic wear consistent with service use. It is inspected prior to dispatch. \u003cstrong\u003eGuarantee:\u003c\/strong\u003e supplied with a \u003cstrong\u003e6-month guarantee\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Grundfos\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e TPD 100-160\/2 A-F-A-BQQE-KW1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct number:\u003c\/strong\u003e 96109245\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStock code:\u003c\/strong\u003e #4950\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePump type:\u003c\/strong\u003e twin-head dry-rotor in-line centrifugal circulator pump\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpeed type:\u003c\/strong\u003e fixed speed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication type:\u003c\/strong\u003e commercial heating, cooling and HVAC circulation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e DN100 inlet \/ DN100 outlet\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e DIN flanged\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure rating:\u003c\/strong\u003e PN16\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum operating pressure:\u003c\/strong\u003e 16 bar\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePort-to-port length:\u003c\/strong\u003e 500 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated motor power:\u003c\/strong\u003e 4 kW per motor head\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 3-phase, 50 Hz, 3 × 380–415V Delta\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal voltage listing:\u003c\/strong\u003e 415V 3-phase\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e approx. 7.9 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePole number:\u003c\/strong\u003e 2-pole\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpeed:\u003c\/strong\u003e approx. 2900 rpm class\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum head reference:\u003c\/strong\u003e 16 m\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlow reference:\u003c\/strong\u003e approx. 6.2–73 m³\/h \/ 1.72–20.28 L\/s, depending on duty point\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShaft seal:\u003c\/strong\u003e BQQE mechanical shaft seal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBQQE seal materials:\u003c\/strong\u003e rubber bellows seal, silicon carbide \/ silicon carbide seal faces, EPDM elastomers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLiquid temperature range with BQQE seal:\u003c\/strong\u003e -25°C to +120°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuitable liquids:\u003c\/strong\u003e thin, clean, non-aggressive, non-flammable circulation liquids compatible with cast iron, EPDM and BQQE shaft seal materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePump housing material:\u003c\/strong\u003e cast iron\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eImpeller material:\u003c\/strong\u003e cast iron \/ standard A-material version\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor protection:\u003c\/strong\u003e PTC thermistors \/ thermal protection connection via amplifier relay\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 5700396982229\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eNeed help confirming suitability?\u003c\/strong\u003e\u003cbr\u003e\nCall us on \u003cstrong\u003e01803 220416\u003c\/strong\u003e for technical advice.\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch3\u003eManufacturer product page\u003c\/h3\u003e\n\n\u003cp\u003e\nThe official Grundfos product page for this pump can be viewed here:\u003cbr\u003e\n\u003ca href=\"https:\/\/product-selection.grundfos.com\/uk\/products\/tp-tpe\/tpd\/tpd-100-1602-96109245\" rel=\"nofollow noopener\" target=\"_blank\"\u003e\nView Grundfos TPD 100-160\/2 A-F-A-BQQE-KW1 – 96109245\n\u003c\/a\u003e\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch3\u003eTechnical documentation\u003c\/h3\u003e\n\n\u003cp\u003e\nGrundfos TP \/ TPD \/ TPE \/ TPED data booklet:\u003cbr\u003e\n\u003ca href=\"https:\/\/api.grundfos.com\/literature\/Grundfosliterature-7124417.pdf\" rel=\"nofollow noopener\" target=\"_blank\"\u003e\nView Grundfos TP, TPD, TPE and TPED data booklet\n\u003c\/a\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\nGrundfos specification sheet and dimensional drawing for product number 96109245:\u003cbr\u003e\n\u003ca href=\"https:\/\/www.anglianpumping.com\/app\/uploads\/2023\/03\/96109245.pdf\" rel=\"nofollow noopener\" target=\"_blank\"\u003e\nView Grundfos 96109245 specification sheet and dimensional drawing\n\u003c\/a\u003e\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eCommercial heating circulation systems\u003c\/li\u003e\n  \u003cli\u003eBoiler primary and secondary circuits\u003c\/li\u003e\n  \u003cli\u003eHVAC circulation systems\u003c\/li\u003e\n  \u003cli\u003eDistrict heating and cooling circuits\u003c\/li\u003e\n  \u003cli\u003eChilled-water circulation, subject to condensation control\u003c\/li\u003e\n  \u003cli\u003eClean industrial circulation duties\u003c\/li\u003e\n  \u003cli\u003eReplacement for existing DN100 flanged Grundfos TPD installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003ch4\u003eWhat is this pump used for?\u003c\/h4\u003e\n\n\u003cp\u003e\nThis Grundfos TPD 100-160\/2 is used for commercial heating, cooling and HVAC circulation duties. It is an in-line centrifugal twin-head pump, designed for moving clean circulation liquids around closed-loop building services systems.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat does TPD mean?\u003c\/h4\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eTPD\u003c\/strong\u003e is Grundfos’ twin-head dry-rotor in-line pump range. A TPD pump has two pump heads mounted on one common pump body, allowing the system to run one head at a time, alternate between heads, or use the second head as standby depending on the installed controls.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat does 100-160\/2 mean?\u003c\/h4\u003e\n\n\u003cp\u003e\nIn the Grundfos model code, \u003cstrong\u003e100\u003c\/strong\u003e refers to the nominal DN100 inlet and outlet connection size. \u003cstrong\u003e160\u003c\/strong\u003e refers to the nominal maximum head class of approximately 16 metres. The \u003cstrong\u003e\/2\u003c\/strong\u003e indicates a 2-pole motor speed version.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat does A-F-A-BQQE-KW1 mean?\u003c\/h4\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e – basic pump version\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF\u003c\/strong\u003e – DIN flanged pipe connection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e – standard cast-iron material version\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBQQE\u003c\/strong\u003e – mechanical shaft seal code\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKW1\u003c\/strong\u003e – motor \/ voltage \/ speed variant suffix\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eWhat is the BQQE shaft seal?\u003c\/h4\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eBQQE\u003c\/strong\u003e is the Grundfos shaft seal code. It indicates a rubber bellows mechanical shaft seal with \u003cstrong\u003esilicon carbide \/ silicon carbide seal faces\u003c\/strong\u003e and \u003cstrong\u003eEPDM elastomers\u003c\/strong\u003e. This is a common seal choice for clean heating and cooling water duties where the liquid is compatible with EPDM.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat temperature range can this pump operate at?\u003c\/h4\u003e\n\n\u003cp\u003e\nFor this \u003cstrong\u003eTPD 100-160\/2 A-F-A-BQQE-KW1\u003c\/strong\u003e version, the fitted \u003cstrong\u003eBQQE shaft seal\u003c\/strong\u003e has a listed liquid temperature range of \u003cstrong\u003e-25°C to +120°C\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe wider TP Series 300 PN16 pump range may be available with alternative shaft seals for higher-temperature duties, but this exact pump is fitted with \u003cstrong\u003eBQQE\u003c\/strong\u003e, so \u003cstrong\u003e-25°C to +120°C\u003c\/strong\u003e is the suitable temperature range to use for this listing.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat liquids is this pump suitable for?\u003c\/h4\u003e\n\n\u003cp\u003e\nThis pump is suitable for \u003cstrong\u003ethin, clean, non-aggressive and non-flammable liquids\u003c\/strong\u003e that do not contain solid particles or fibres which could attack the pump mechanically or chemically.\n\u003c\/p\u003e\n\n\u003cp\u003e\nFor this BQQE version, suitable liquid examples include:\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCentral heating system water\u003c\/strong\u003e – water quality must meet accepted heating-system standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDistrict-heating water\u003c\/strong\u003e – up to 120°C with the fitted BQQE seal\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCooling water \/ chilled-water circuits\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHot tap water \/ domestic hot-water circulation\u003c\/strong\u003e, subject to system design and material suitability\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBoiler-feed water\u003c\/strong\u003e – up to 120°C with BQQE, subject to water quality\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondensate\u003c\/strong\u003e – up to 120°C with BQQE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSoftened water\u003c\/strong\u003e – up to 120°C with BQQE; oxygen-free conditions may be required depending on duty\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClean industrial circulation liquids\u003c\/strong\u003e compatible with cast iron, EPDM and silicon carbide \/ silicon carbide seal faces\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eCan this pump be used with glycol or antifreeze mixtures?\u003c\/h4\u003e\n\n\u003cp\u003e\nYes, subject to the exact mixture and operating conditions. Grundfos states that if glycol or another antifreeze agent is added to the pumped liquid, the pump must have a \u003cstrong\u003eBQQE\u003c\/strong\u003e or \u003cstrong\u003eDQQE\u003c\/strong\u003e shaft seal. This pump is fitted with \u003cstrong\u003eBQQE\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nSuitable coolant \/ antifreeze examples listed for BQQE include:\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEthylene glycol mixtures\u003c\/strong\u003e – up to 120°C, subject to concentration, viscosity and system design\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePropylene glycol mixtures\u003c\/strong\u003e – up to 120°C, subject to concentration, viscosity and system design\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlycerine \/ glycerol mixtures\u003c\/strong\u003e – up to 120°C, subject to concentration and viscosity\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePotassium acetate brines\u003c\/strong\u003e – up to 120°C in standard guidance, with some conditions listed separately up to 110°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePotassium formate brines\u003c\/strong\u003e – up to 120°C, subject to concentration and system design\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSodium chloride brine\u003c\/strong\u003e – listed at up to 30% and below 5°C, subject to corrosion risk and system design\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\nGlycol and brine mixtures can have higher density and viscosity than water. This can reduce hydraulic performance, increase pressure loss and increase motor load, so the final duty should be checked before use.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat treated-water or chemical duties are listed for BQQE?\u003c\/h4\u003e\n\n\u003cp\u003e\nGrundfos lists a number of treated-water and chemical duties where \u003cstrong\u003eBQQE\u003c\/strong\u003e is shown as the selected shaft seal for TP Series 300 PN16 applications. These should be treated as guidance only, because concentration, temperature, pressure, water quality and additives all affect compatibility.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHydrogen peroxide\u003c\/strong\u003e – below 40°C and below 2%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmmonium bicarbonate\u003c\/strong\u003e – below 20°C and below 15%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCalcium acetate\u003c\/strong\u003e – below 20°C and below 30%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePotassium bicarbonate\u003c\/strong\u003e – below 20°C and below 20%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePotassium carbonate\u003c\/strong\u003e – below 20°C and below 20%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePotassium permanganate\u003c\/strong\u003e – below 20°C and below 10%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePotassium sulphate\u003c\/strong\u003e – below 20°C and below 20%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSodium acetate\u003c\/strong\u003e – below 20°C and below 100%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSodium bicarbonate\u003c\/strong\u003e – below 20°C and below 2%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSodium carbonate\u003c\/strong\u003e – below 20°C and below 20%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSodium nitrate\u003c\/strong\u003e – below 0°C and below 40%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSodium nitrite\u003c\/strong\u003e – below 20°C and below 40%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisodium phosphate\u003c\/strong\u003e – below 100°C and below 30%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrisodium phosphate\u003c\/strong\u003e – below 90°C and below 20%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSodium sulphate\u003c\/strong\u003e – below 20°C and below 20%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSodium sulphite\u003c\/strong\u003e – below 20°C and below 1%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmmonium hydroxide\u003c\/strong\u003e – below 100°C and below 30%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCalcium hydroxide\u003c\/strong\u003e – below 100°C and below 10%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePotassium hydroxide\u003c\/strong\u003e – below 20°C and below 20%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSodium hydroxide\u003c\/strong\u003e – below 40°C and below 20%\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eWhat liquids should this pump not be used for?\u003c\/h4\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\u003cstrong\u003eDirty water, wastewater, sewage, sludge, solids or fibres\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eFlammable liquids\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eLiquids that chemically attack cast iron, EPDM or the BQQE shaft seal materials\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMineral oils, synthetic oils, vegetable oils and fuel-related liquids\u003c\/strong\u003e unless the seal and elastomers are specifically reviewed and changed if required\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeawater or aggressive saline duties\u003c\/strong\u003e unless the full material selection is confirmed as suitable\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eIs this suitable for potable water?\u003c\/h4\u003e\n\n\u003cp\u003e\nThis is a cast-iron commercial circulator and is not normally selected for potable domestic hot-water duties. For potable or domestic hot-water applications, pump material, water quality, temperature, system design and local regulations must be checked carefully. Stainless-steel or bronze versions are usually preferred where potable-water compatibility is required.\n\u003c\/p\u003e\n\n\u003ch4\u003eIs this a variable-speed pump?\u003c\/h4\u003e\n\n\u003cp\u003e\nNo. This is a \u003cstrong\u003efixed-speed TPD pump\u003c\/strong\u003e, not a TPE or TPED electronically controlled version. Any duty\/standby or alternating operation would normally be handled by the external control panel or BMS arrangement on site.\n\u003c\/p\u003e\n\n\u003ch4\u003eCan both pump heads run at the same time?\u003c\/h4\u003e\n\n\u003cp\u003e\nThe pump body contains two pump heads, but how they operate depends on the system controls. In many installations, twin-head pumps are used for duty\/standby or automatic alternation, with one head running while the other remains available as backup. Some systems may use both heads depending on the control arrangement, but this should be checked against the site design.\n\u003c\/p\u003e\n\n\u003ch4\u003eWill this replace my existing DN100 TPD pump?\u003c\/h4\u003e\n\n\u003cp\u003e\nThis pump has \u003cstrong\u003eDN100 DIN flanged connections\u003c\/strong\u003e, \u003cstrong\u003ePN16 pressure rating\u003c\/strong\u003e and a \u003cstrong\u003e500 mm port-to-port length\u003c\/strong\u003e. It may be a suitable replacement for existing matching Grundfos TPD 100-160\/2 installations, but the product number, flange standard, port-to-port length, voltage, motor power and duty point should be checked before ordering.\n\u003c\/p\u003e\n\n\u003ch4\u003eWhat electrical supply does it need?\u003c\/h4\u003e\n\n\u003cp\u003e\nThis pump is a \u003cstrong\u003e3-phase 50 Hz unit\u003c\/strong\u003e with a \u003cstrong\u003e3 × 380–415V Delta\u003c\/strong\u003e motor configuration. Electrical installation should be carried out by a qualified person using suitable overload protection and control gear.\n\u003c\/p\u003e\n\n\u003ch4\u003eDoes this pump need a control panel?\u003c\/h4\u003e\n\n\u003cp\u003e\nThe pump itself is fixed speed. Twin-head operation, duty\/standby changeover, overload protection and any BMS integration are normally handled by the external control panel or site controls. The motor protection thermistors should be connected to suitable protection equipment where required.\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch3\u003eAbout Our Stock\u003c\/h3\u003e\n\n\u003cp\u003e\nStock code: \u003cstrong\u003e#4950\u003c\/strong\u003e\u003cbr\u003e\nWe specialise in supplying \u003cstrong\u003eused, surplus and obsolete commercial pump equipment\u003c\/strong\u003e. This pump is supplied as a \u003cstrong\u003eused pump\u003c\/strong\u003e and will be inspected prior to dispatch.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThis item is supplied with a \u003cstrong\u003e6-month guarantee\u003c\/strong\u003e. Please check the product number, flange size, voltage, port-to-port length and duty requirements carefully before purchase.\n\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":63775603097977,"sku":null,"price":1800.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1218\/7894\/files\/34ddf2a3-47f6-42b2-a6ee-94deae889fe7.jpg?v=1781609439","url":"https:\/\/thepumpdealer.co.uk\/products\/grundfos-tpd-100-160-2-a-f-a-bqqe-kw1-flanged-pump-heating-circulator-415v-dn100-96109245-4950","provider":"The Pump Dealer","version":"1.0","type":"link"}