These figures provide simplified information for searching, filtering and initial comparison. They are not a complete specification. Exact details depend on the model and configuration.
Power rating: Usually the motor’s rated mechanical output (P2). Electrical input power (P1) is a different value. Check the product’s nameplate or manufacturer’s documentation to confirm which rating applies.
Outlet size: The nominal size class is expressed on a millimetre basis: for example, DN40 denotes a nominal 40 mm size. It does not specify the exact measured opening, connection type, thread, flange drilling or pressure rating.
Head and flow: Indicative figures describing the pump’s performance envelope, rather than a single operating duty point. Do not assume maximum flow is available at maximum head, or that every combination within the ranges is achievable. Minimum figures do not establish safe continuous operating limits. Consult the relevant performance curve.
Check the product description, nameplate and manufacturer’s documentation before selection or installation. Please contact us before purchasing if you need help confirming suitability or connection details.
| Nominal voltage | 240v |
| Rated power | 0.073 kW |
| Nominal outlet size (mm) | DN 25 |
| Port-to-Port Length | 180.0 mm |
| Shipping Weight | 10.0 kg |
| Package Dimensions | 25.0 × 25.0 × 25.0 cm |
| Indicative minimum head | 1.0 m head (0.1 bar) |
| Indicative maximum head | 8.5 m head (0.8 bar) |
| Indicative maximum flow | 4.8 m³/h (1.3 L/s) |
This listing is for a Grundfos UPM GEO 25-85 180 high-efficiency canned-rotor circulator pump. The UPM GEO range is designed for cold-water applications, geothermal heat pumps, heating systems and air-conditioning systems where remote speed control is required via a low-voltage PWM signal.
Condition: supplied in as new surplus condition – the unit has not been installed or used but may show minor cosmetic markings from storage and handling. Guarantee: supplied with a 2-year guarantee.
Need help confirming suitability?
Call us on 01803 220416 for technical advice.
Full technical specifications and performance data can be viewed here:
View Grundfos UPM2 / UPM GEO / UPM2K technical data booklet
230 V~ means 230 volt AC supply. This pump is rated for 50/60 Hz.
This pump is externally speed-controlled by a low-voltage PWM signal from a system controller, such as a heat pump or OEM control unit. A suitable three-core signal cable is required, with signal input, signal output and signal reference. Without the control signal, the pump will run at maximum speed.
It may be suitable where the existing unit is a matching UPM GEO 25-85 180 or compatible OEM variant. Please compare the product number, port-to-port length, threaded connection, supply voltage, PWM control type and connector arrangement before ordering.
The UPM GEO range is suitable for thin, clean, non-aggressive and non-explosive liquids that do not contain solid particles, fibres or mineral oil.
UPM GEO pumps can be used with water/antifreeze mixtures such as glycol or ethanol down to -10 °C. Higher viscosity from glycol mixtures can reduce performance and increase system pressure loss, so the mixture type, concentration and operating temperature should be checked against the system design.
Not suitable for:
No. UPM GEO is a canned-rotor circulator, where the pump and motor form an integrated unit without a conventional mechanical shaft seal.
No external motor protection is normally required. The pump includes internal overload protection, but the electrical connection must still be carried out correctly and in accordance with local regulations.
Stock code: #4839
We specialise in supplying new and unused surplus pumps. All units are inspected prior to dispatch and supplied with a 2-year guarantee.
Specification & guidance notice: Technical information and FAQ content are provided in good faith based on manufacturer literature and industry experience. Descriptions of hydraulic types and application suitability represent general guidance only and do not constitute a guarantee of performance. Actual results will depend on system design, pipework losses, media characteristics, and installation conditions. Please consult the manufacturer & thier documentation and satisfy yourself that the equipment is suitable for your specific application prior to purchase.