    Technical Information

    Voltage 415v
    Power Rating 1.7 kW
    Outlet Size DN 50
    Shipping Weight 48.0 kg
    Package Dimensions 45.0 × 35.0 × 35.0 mm
    Minimum Pressure 5.0 m head (0.5 bar)
    Maximum Pressure 21.0 m head (2.1 bar)
    Minimum Flow 0.0 m³/h (0.0 L/s)
    Maximum Flow 46.8 m³/h (13.0 L/s)

    In stock: 1


    Flygt 3068.180 HT 253 – 1.7kW Submersible Pump (3~) #4158

    The Flygt 3068 is a robust submersible pump suitable for pumping clean water, surface water and waste water containing solids or fibred material. This series is widely used in municipal and industrial installations where dependable operation and solids handling are required.

    Flygt is a premium pump manufacturer and part of the Xylem Group, widely recognised for producing high-quality wastewater and drainage pumps used globally.

    This pump is supplied as new, unused surplus stock and has not been installed. Minor cosmetic marks may be present from storage.

    • Flygt C-type hydraulic (channel / single-vane style) for efficient wastewater pumping
    • Guide-rail arrangement – slides down guide rails and docks onto the discharge connection at the base
    • HT motor class – high head configuration
    • Impeller code: 253
    • Supplied with 2 year guarantee

    Need help confirming suitability?
    Call us on 01803 220416 for technical advice.


    Quick “Which should I pick?” cheat sheet

    • Choose C-type (this pump) when you want good efficiency and reliable solids handling for wastewater and surface water duties, and you are not dealing with extreme ragging conditions.
    • Choose Vortex when the duty is primarily about maximum solids tolerance and passage, and you can accept the normal efficiency trade-off.
    • Choose Flygt N / Adaptive N when modern ragging sewage is the main problem and you want a hydraulic designed to maintain performance over time and reduce call-outs.

    Delivery & Shipping

    • Next working day dispatch available (order before 4pm)
    • Same-day courier available – please call for a quote
    • UK and international delivery available
    • International shipping costs confirmed after checkout

    Manufacturer specification:
    Full technical details can be found in the manufacturer’s documentation:
    View official Flygt specification sheet

    Technical note – voltage:
    Voltage is shown as 415V in the listing for simplified search purposes. The motor nameplate configuration for this pump is 400V Star / 230V Delta. Electrical connection must always follow the motor nameplate and be carried out by a qualified electrician in accordance with manufacturer instructions.


    Frequently Asked Questions

    What does the model number mean?

    • 3068 – Pump model series
    • .180 – Standard non-explosion-proof version
    • HT – High head motor / pressure class
    • 253 – Impeller code
    • 1.7kW (3~) – Motor rated power and three-phase supply

    What applications is this pump suitable for?

    Suitable for pumping clean water, surface water and waste water containing solids or fibred material. Common uses include drainage, storm water, site water, industrial sumps and wastewater wet-well duties.

    What is a C-type impeller?

    On the Flygt C-pump range, the hydraulic is a channel-impeller design. For the Flygt 3068 specifically, it is a shrouded single-vane impeller with strong flow-passing properties, intended to reduce the risk of clogging in the impeller channel.

    Why would I choose a C-type instead of a vortex impeller?

    Vortex pumps are chosen when maximum solids tolerance is the priority. A C-type is chosen when you want more conventional pumping action with strong duty performance and solids handling.

    Why would I choose a C-type instead of Flygt N-type?

    A C-type hydraulic is typically selected when the duty is predictable and not dominated by modern ragging sewage. It offers conventional centrifugal behaviour with good efficiency at a defined duty point and simple, familiar construction.

    Flygt N-type is aimed at sites where wipes and long fibres cause gradual performance loss and blockages. If your station historically runs well on channel impellers, C-type is often the more appropriate and economical choice. If the site suffers repeated ragging and call-outs, N-type may be the better long-term solution.

    What’s the difference between vortex, C-type and “non-clog”?

    • Vortex – prioritises solids passage; efficiency trade-offs are common.
    • C-type – conventional hydraulic with good efficiency and solids handling.
    • “Non-clog” – broad term, often used for channel/single-vane solids-handling designs.

    Can this replace my existing Flygt pump?

    In many cases, yes. Send your model number and photos of your installation and we can advise.

    Do you offer technical support?

    Yes — call 01803 220416.


    About Our Stock

    We supply new and unused surplus pumps inspected prior to dispatch and supplied with guarantee.

    Specification & guidance notice: Technical information and FAQ content are provided in good faith based on manufacturer literature and industry experience. Descriptions of hydraulic types and application suitability represent general guidance only and do not constitute a guarantee of performance. Actual results will depend on system design, pipework losses, media characteristics, and installation conditions. Please consult the manufacturer & thier documentation and satisfy yourself that the equipment is suitable for your specific application prior to purchase.